Thermocouples are simple, rugged and cover a very wide temperature range. The letter type decides how hot they can go, how stable they are and what they cost.

Oct 20264 min readEECG Engineering Team
Type KType R/SType BThermowells

How a thermocouple works

Two different metals joined at the measuring point produce a small voltage that depends on the temperature difference between that junction and the reference (cold) junction at the instrument. Thermocouple types are defined in IEC 60584 by their metal pairs.

Common types at a glance

TypeMetalsApproximate upper range*Typical uses
KNickel-chromium / nickel-aluminiumabout 1200 °CGeneral purpose: furnaces, flue gas, process
JIron / copper-nickelabout 750 °CPlastics, older equipment, reducing atmospheres
TCopper / copper-nickelabout 350 °CLow and sub-zero temperatures
NNicrosil / nisilabout 1250 °CMore stable alternative to K at high temperature
R and SPlatinum-rhodium / platinumabout 1600 °CSteel, glass, heat treatment, reference sensors
BPlatinum-rhodium / platinum-rhodiumabout 1700 °CVery high temperatures: steel melting, kilns

*Practical limits depend on wire diameter, sheath, atmosphere and required life. Check the specification for your application.

Base metal vs noble metal

Base-metal types (K, J, T, N) are economical and widely used. Noble-metal types (R, S, B) cost more but are stable at high temperatures where base metals drift or fail.

Construction: mineral insulated and thermowells

Mineral-insulated (MI) thermocouples have wires packed in compacted magnesium oxide inside a metal sheath — robust, bendable and fast-responding. A thermowell protects the sensor from pressure, flow and corrosion and lets it be replaced without opening the process. Ceramic protection tubes are used at very high temperatures.

Extension and compensating cables

Connect thermocouples to instruments with cable of the matching type; ordinary copper cable introduces errors at the junctions. Extension cables use the same alloys as the thermocouple; compensating cables use alloys with matching output over a limited temperature range.

Thermocouple or RTD?

RTDs are more accurate and stable at moderate temperatures; thermocouples cover much higher temperatures and harsh conditions. See our RTD vs thermocouple comparison.

Frequently asked questions

Why does my thermocouple read wrong?

Typical causes are the wrong cable type, reversed polarity, drift after long high-temperature use, or a damaged sheath. Calibration against a reference sensor confirms the reading.

Browse Tempsens products at EECG

EECG is an authorised channel partner for Tempsens in Central India, with supply, installation and service support from our Raipur team.

Tempsens range → Search our catalogue for “thermocouple” →

Need help selecting the right product for your process conditions? Share your duty and our engineers will recommend a model and send a quotation.

Talk to an engineer →

Related articles

Industrial Temperature Measurement: RTD vs Thermocouple and How to Choose the Right Sensor 7 min read How to Select a Pressure Transmitter: Gauge, Absolute and Differential Pressure 4 min read Industrial Plant Maintenance Services in Raipur: AMC, CAMC, Calibration & O&M Support 6 min read All articles →